September 18, 2017

LOOP SOUR QUALITY MESSAGE

By Public Information Officer

The charts below show the quality characteristics of LOOP Sour Crude Oil deliveries to connecting carrier pipelines for the week of September 11th, 2017.


LOOP will be issuing similar reports on a weekly basis. Please check loopllc.com for updates.
 
Density is determined by continuous density measurement utilizing online densitometers and the weighted-average reading obtained during the batch delivery for the gross standard volume calculation. Density results are then verified using API Manual of Petroleum Measurement Publications (MPMS), Chapter 9 Section 3 “Standard Test Method for Density, Relative Density, and API Gravity of Crude Petroleum and Liquid Petroleum Products by Thermohydrometer Method” for the net standard volume calculation.   
 
Sulfur is determined by the use of a Horiba Sulfur-in-Oil Analyzer. This instrument uses Energy Dispersive X-ray Fluorescence to determine total Sulfur in Petroleum products. ASTM method D4294 “Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy Dispersive X-ray Fluorescence Spectrometry” is used. Note, this field lab test is conducted on an observed composite sample without water distillation.


 

Read More
September 08, 2017

LOOP Update 1 - Hurricane Irma

By Public Information Officer

LOOP is actively monitoring Hurricane Irma. 

All LOOP facilities are currently reporting normal operations.

LOOP will update its status periodically throughout the storm.

Read More
September 01, 2017

Clovelly Hub 6 Month Capacity Outlook

By Public Information Officer

September 1, 2017

LOOP tracks the amount of capacity in service at the Clovelly Hub monthly.  A six month capacity forecast follows in the table below.
 
LOOP performs rigorous maintenance, inspection and testing of its facilities, including its above ground tankage and underground caverns.  At specified intervals, these activities require LOOP to remove assets from active service, thus reducing capacity. Those maintenance and construction activities are just a fraction of the work performed, within the LOOP Safety Management System framework, to continually improve the operation.          
 

LOOP Clovelly Hub 6 Month Capacity Outlook
2017 Total Above Ground Capacity Underground Capacity
September 99% 95% 100%
October 88% 95% 87%
November 88% 95% 87%
December 88% 95% 87%
January 88% 95% 87%
February 88% 95% 87%

Read More
September 01, 2017

LOOP SOUR QUALITY MESSAGE

By Public Information Officer


September 1, 2017
 
For the month of August 2017 LOOP has delivered over 850,000 barrels of LOOP Sour Crude Oil from LOOP Sour Storage. The chart below shows the quality characteristics of LOOP Sour Crude Oil deliveries to connecting carrier pipelines for the month of August 2017.  The utilization rate of the CACs for the month of August was 81.17%
 

  API Gravity Sulfur (%)
Max 30.7 2.85
Volumetric Avg. 29.84 2.57
Min 29.3 2.16
 
LOOP will be issuing similar reports on a monthly basis. Please check loopllc.com for updates.
 
Density is determined by continuous density measurement utilizing online densitometers and the weighted-average reading obtained during the batch delivery for the gross standard volume calculation. Density results are then verified using API Manual of Petroleum Measurement Publications (MPMS), Chapter 9 Section 3 “Standard Test Method for Density, Relative Density, and API Gravity of Crude Petroleum and Liquid Petroleum Products by Thermohydrometer Method” for the net standard volume calculation.   
 
Sulfur is determined by the use of a Horiba Sulfur-in-Oil Analyzer. This instrument uses Energy Dispersive X-ray Fluorescence to determine total Sulfur in Petroleum products. ASTM method D4294 “Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy Dispersive X-ray Fluorescence Spectrometry” is used. Note, this field lab test is conducted on an observed composite sample without water distillation.
 
 

Read More